Philips AVENT SCD340/31 Breastfeeding set with electric breast pump

Variants
SCF395/31 Electric Breast Pump
SCF395/31 Electric Breast Pump
With code from 81.59 €
In stock
SCD340/31 Breastfeeding set with electric breast pump
SCD340/31 Breastfeeding set with electric breast pump
With code from 116.24 €
In stock
SCF397/31 Double Electric Breast Pump
SCF397/31 Double Electric Breast Pump
158.90 € 
In stock
Buy with code ALZADNI25
116.24 €
Great price 154.99 € Save 5.10 €
Installment calculator 4,9%  interest from 2.67 € monthly

Philips AVENT SCD340/31 Breastfeeding set with electric breast pump

The Philips Avent Breastfeeding Starter Set combines Natural Motion technology for fast milk flow with a soft silicone pad for maximum comfort. The set is the ideal choice for moms looking for a practical solution for pumping, storing and feeding breast milk. Choose simplicity and efficiency and get more free time for your baby.

Philips AVENT electric breast pump SCD340/31

Key Features of the Philips AVENT Breastfeeding Starter Set

  • Gently adapts to the shape of the breasts thanks to the soft silicone pad
  • Offers multiple stimulation and suction modes for maximum comfort
  • Promotes natural latch-on and eases the transition between breastfeeding and bottle feeding
  • Safely stores breast milk thanks to the storage cup
  • Facilitates travel with breast milk
  • Storage cup and suction cup suitable for sterilisation

Technical specifications and package contents

8 stimulation modes
16 suction modespower supply - 100 V-240 V

The package contains:
1× bottle brush
4× disposable breast pads
1× suction kit
1× motor unit (use with cable only)
1× sealing cap
2× extra soft soothers 0-6 months
2× 260 ml bottles
1× 125 ml bottle
1× slow flow soother
5× VIA cups with lids 180 ml
1× micro-USB adapter
1× adapter

Using the Philips AVENT breast pump

Clean and disinfect before first use and after each use. Wipe with a clean, damp cloth soaked in water and a mild cleaning agent.
All parts that come into contact with breast milk can be washed by hand or in the dishwasher. Do not use antibacterial or abrasive cleaners to clean the breast pump as they can cause damage. Never submerge the motor or adapter in water or insert the receptacles, as this will irreparably damage these components. Be careful when removing the white valve and cleaning it. If it is damaged, the extractor will not work properly. To remove the white valve, gently pull the knurled tab on the side of the valve. Clean the white valve by gently rubbing it between your fingers in warm water with added dishwashing liquid. Do not insert objects into the white valve, it could be damaged.
Manual cleaning:
Step 1: Wash all parts under lukewarm running water.
Step 2: Soak all parts in warm water with a little mild dishwashing liquid for 5 minutes.
Step 3: Clean all parts with a soft brush.
Step 4: Thoroughly rinse all parts under potable running water.
Step 5: Allow all parts to air dry on a clean cloth or drip tray.


Dishwasher safe:
Step 1: Place all parts in the top basket in the dishwasher.
Step 2: Add the detergent or tablet to the dishwasher and start the normal programme.
Step 3: Allow all parts to air dry on a clean cloth or drip tray.
Do not allow the bottle and other parts to touch the side of the pot during disinfection with boiling water. Irreversible product deformation or damage could occur.
Insert size:
The Philips Avent Premium single or double breast pump includes a soft massage insert. It gently stimulates the nipple to get the milk flowing. The insert is made of flexible silicone that fits up to 99.98% of women, nipple size up to 30 mm.
Assembling the breast pump:
Make sure that you have cleaned and disinfected all parts of the breast pump that come into contact with breast milk. If you have disinfected the pump parts by boiling, be careful, they can get really hot. To avoid burns, start assembling the breast pump after the disinfected parts have cooled down. Before touching the breast pump and breast parts, wash your hands thoroughly with soap and water to prevent contamination. Do not touch the inside of containers or lids if possible. Before use, check that the extractor components are not worn or damaged. Replace them if necessary.
Step 1: Wash your hands properly with soap and water. Step 2: Insert the white valve into the body of the suction hood. Step 3: Screw the body of the breast pump onto the bottle. Step 4: Insert the liner into the body of the breastmilk pump and make sure that the edge fits over the body of the pump.4A Press the inner part of the liner into the anti-clotting funnel (marked with an arrow). Step 5: Insert the silicone diaphragm into the body of the breast pump. Press the silicone diaphragm down with your fingers so that it seals perfectly around the edge of the breast pump. Step 6: A silicone tube and cap are attached to the silicone diaphragm. Push the cap in until it clicks firmly into place. Step 7: Hoses connected to the motor unit. Step 8: Connect the adapter to the power socket and the plug at the other end to the motor unit. Step 9: Now the breast pump is ready for use.
Before you get ready to pump, you can put a cover on the massage pad to keep the breastmilk pump clean.
Milk expressing instructions:
Always switch off the breast pump first to relieve the vacuum before removing the pump body from the breast. If you are unable to express any milk, do not continue pumping for more than five minutes at a time. Try sucking at a different time of day. If pumping becomes very uncomfortable or painful, stop using the pump and consult your doctor.
If you regularly pump more than 125 ml in one use, you can purchase and use the Philips Avent Natural 260 ml bottle to prevent overfilling or spillage. Note: The breast pump can be used without a cord if it is sufficiently charged, but you can also use it plugged into a socket.
Step 1: Wash your breasts thoroughly with soap and water and make sure that they are clean.
Step 2: Put the breast pump kit on. Make sure to fuck the cow in the middle.
Step 3: Press the on/off button. The indicator light comes on to indicate that the device is in stimulation mode.
Step 4: The pump starts the stimulation mode and slowly increases the pressure to the stimulation intensity level used last time (in case of first use to level 5).
Step 5: You can freely change the intensity of the sound using the increase and decrease buttons.
Step 6: After 90 seconds, the extractor starts the suction mode and slowly increases the vacuum to the suction intensity level used last time (in the case of first use to level 11).
Step 7: If you want to switch from suction mode to stimulation mode, you can switch modes using the mode selector button.
Step 8: To stop the extractor, shortpress the buttonswitches. To continue, press the switch button once more.
Step 9: Press and hold the switch to switch the device off.

Safety notice

For the safety and health of your child:
Always use the bottle under adult supervision.
Do not use feeding pacifiers to soothe your baby as there is a risk of choking.
Persistent and prolonged sucking of liquids causes tooth decay.
Always check the temperature of the food before you feed your baby.
Keep all parts not in use out of the reach of children.
Keep the cap of the bottle out of the reach of children to prevent them from choking on it.
Do not allow children to play with small parts or to walk or run while using the bottle.
Check all parts before each use and stretch the feeding pacifier in all directions.
Discard any part if it shows any signs of damage or wear.
Always pour off any milk left after feeding.
How to prevent bottle damage:
Do not place the product in a hot oven, the plastic may melt.
Plastic products may be subject to disinfection and high temperatures. This may change the fit of the bottle cap. Do not leave the feeding soother in direct sunlight, expose it to heat or leave it in disinfectant for longer than the recommended time, as this could damage it.
Varation:
Do not use a breast pump during pregnancy as suction can induce labour.

Specifications

Type

Type electrical

Suction phase

Suction type 2-phase

Volume

Volume 260 ml

Function

Features and functions Ergonomic design, Quiet operation

Power supply

Power Supply Mains-powered
Code:  BABY3817
Warranty: 24 months
Links: Producer's Website:
Manufacturer information

Philips Consumer Lifestyle B.V., Tussendiepen 4, 9206 AD Drachten, The Netherlands, [email protected]

Show more